/[corp_html]/fc/CustomManuf-Page4.htm
This is repository of my old source code which isn't updated any more. Go to git.rot13.org for current projects!
ViewVC logotype

Annotation of /fc/CustomManuf-Page4.htm

Parent Directory Parent Directory | Revision Log Revision Log


Revision 1.1 - (hide annotations)
Thu Feb 22 20:47:18 2001 UTC (23 years, 2 months ago) by dpavlin
Branch: MAIN
CVS Tags: HEAD
File MIME type: text/html
fine chemicals

1 dpavlin 1.1 <p><b>Full Scale Production</b></p>
2     <table width="516" border="0" cellspacing="0" cellpadding="0">
3     <tr>
4     <td width="516" valign="top">
5     <p><b>PLIVA has modern full scale production facilities able to accommodate
6     all your needs from kg to multitons allowing you to save time and costs.</b>
7     </p>
8     <table width="500" border="0" cellspacing="0" cellpadding="0">
9     <tr>
10     <td valign="top" width="25"><img src="fc/point_2.gif" width="35" height="12"></td>
11     <td width="475">GMP production facilities, located at Zagreb (PBF) and
12     Savski Marof (SM) sites.</td>
13     </tr>
14     <tr>
15     <td valign="top" width="25"><img src="fc/point_2.gif" width="35" height="12"></td>
16     <td width="475">Combine small, medium and large scale units with a wide
17     range of technologies.</td>
18     </tr>
19     <tr>
20     <td valign="top" width="25"><img src="fc/point_2.gif" width="35" height="12"></td>
21     <td width="475"> Effective technology transfer.</td>
22     </tr>
23     <tr>
24     <td valign="top" width="25"><img src="fc/point_2.gif" width="35" height="12"></td>
25     <td width="475">Long term investment plan for continuous upgrading.</td>
26     </tr>
27     </table>
28     <p><b>PBF Site - Four Plants</b></p>
29     <p> <font color="#CC6633">SYNTHESIS I </font></p>
30     <table width="500" border="0" cellspacing="0" cellpadding="0">
31     <tr>
32     <td width="186"><img src="fc/pliva_06.jpg" width="204" height="204"></td>
33     <td width="314" valign="middle">
34     <table width="300" border="0" cellspacing="0" cellpadding="0">
35     <tr>
36     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
37     <td width="282">total volume: 73 m3 reactors/crystallizer</td>
38     </tr>
39     <tr>
40     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
41     <td width="282">unit volume: 0.1 - 4.0 m3</td>
42     </tr>
43     <tr>
44     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
45     <td width="282">material: glass lined, stainless steel</td>
46     </tr>
47     <tr>
48     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
49     <td width="282">temp. range: -10 to 130°C</td>
50     </tr>
51     <tr>
52     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
53     <td width="282">centrifuges</td>
54     </tr>
55     <tr>
56     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
57     <td width="282">filters (vacuum, pressure)</td>
58     </tr>
59     <tr>
60     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
61     <td width="282">dryers (vacuum, fluid-bed)</td>
62     </tr>
63     <tr>
64     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
65     <td width="282">solvent recovery system</td>
66     </tr>
67     <tr>
68     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
69     <td width="282">waste water pretreatment</td>
70     </tr>
71     </table>
72     </td>
73     </tr>
74     </table>
75     <p><font color="#CC6633">SYNTHESIS II </font></p>
76     <table width="500" border="0" cellspacing="0" cellpadding="0">
77     <tr>
78     <td width="186"><img src="fc/Pliva_09.jpg" width="204" height="204"></td>
79     <td width="314" valign="middle">
80     <table width="300" border="0" cellspacing="0" cellpadding="0">
81     <tr>
82     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
83     <td width="282">total volume: 135 m3 reactors/crystallizer</td>
84     </tr>
85     <tr>
86     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
87     <td width="282">unit volume: 0.5 - 20 m3</td>
88     </tr>
89     <tr>
90     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
91     <td width="282">material: glass lined, stainless steel</td>
92     </tr>
93     <tr>
94     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
95     <td width="282">temp. range: -10 to 120°C </td>
96     </tr>
97     <tr>
98     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
99     <td width="282">centrifuges</td>
100     </tr>
101     <tr>
102     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
103     <td width="282">filters (vacuum, pressure)</td>
104     </tr>
105     <tr>
106     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
107     <td width="282">dryers (vacuum, fluid-bed)</td>
108     </tr>
109     <tr>
110     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
111     <td width="282">evaporators</td>
112     </tr>
113     <tr>
114     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
115     <td width="282">solvent recovery system</td>
116     </tr>
117     <tr>
118     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
119     <td width="282">waste water pretreatment </td>
120     </tr>
121     </table>
122     </td>
123     </tr>
124     </table>
125     <p><font color="#CC6633">SULFONAMIDE PLANT</font> </p>
126     <table width="500" border="0" cellspacing="0" cellpadding="0">
127     <tr>
128     <td width="186"><img src="fc/pliva_08.jpg" width="204" height="204"></td>
129     <td width="314" valign="middle">
130     <table width="300" border="0" cellspacing="0" cellpadding="0">
131     <tr>
132     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
133     <td width="282">total volume: 316 m3 reactors/crystallizer</td>
134     </tr>
135     <tr>
136     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
137     <td width="282">unit volume: 0.1 - 6.3 m3 </td>
138     </tr>
139     <tr>
140     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
141     <td width="282">material: glass lined, stainless steel</td>
142     </tr>
143     <tr>
144     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
145     <td width="282">temp. range: -10 to 150°C</td>
146     </tr>
147     <tr>
148     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
149     <td width="282">centrifuges</td>
150     </tr>
151     <tr>
152     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
153     <td width="282">filters (vacuum, ultra, pressure)</td>
154     </tr>
155     <tr>
156     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
157     <td width="282">dryers (fluid-bed) </td>
158     </tr>
159     <tr>
160     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
161     <td width="282">solvent recovery system</td>
162     </tr>
163     <tr>
164     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
165     <td width="282">waste water pretreatment </td>
166     </tr>
167     </table>
168     </td>
169     </tr>
170     </table>
171     <p><font color="#CC6633">BIOSYNTHESIS PLANT</font> </p>
172     <table width="500" border="0" cellspacing="0" cellpadding="0">
173     <tr>
174     <td width="186"><img src="fc/pliva_01.jpg" width="204" height="204"></td>
175     <td width="314" valign="middle">
176     <table width="300" border="0" cellspacing="0" cellpadding="0">
177     <tr>
178     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
179     <td width="282">total volume: 103 m3 reactors/crystallizer</td>
180     </tr>
181     <tr>
182     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
183     <td width="282">unit volume: 0.5 - 30 m3</td>
184     </tr>
185     <tr>
186     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
187     <td width="282">material: glass lined, stainless steel</td>
188     </tr>
189     <tr>
190     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
191     <td width="282">temp. range: -10 to 150°C</td>
192     </tr>
193     <tr>
194     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
195     <td width="282">filters (vacuum, ultra, pressure)</td>
196     </tr>
197     <tr>
198     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
199     <td width="282">evaporators</td>
200     </tr>
201     <tr>
202     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
203     <td width="282"> waste water pretreatment </td>
204     </tr>
205     </table>
206     </td>
207     </tr>
208     </table>
209     <p><b>SM Site - Two Plants</b> </p>
210     <p><font color="#CC6633">SYNTHESIS SM1 PLANT</font> </p>
211     <table width="500" border="0" cellspacing="0" cellpadding="0">
212     <tr>
213     <td width="186"><img src="fc/pliva_08a.jpg" width="204" height="270"></td>
214     <td width="314" valign="middle">
215     <table width="300" border="0" cellspacing="0" cellpadding="0">
216     <tr>
217     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
218     <td width="282">total volume: 107 m3 reactors/crystallizer</td>
219     </tr>
220     <tr>
221     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
222     <td width="282">unit volume: 0.5 - 8.0 m3</td>
223     </tr>
224     <tr>
225     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
226     <td width="282">material: glass lined, stainless steel</td>
227     </tr>
228     <tr>
229     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
230     <td width="282">temp. range: -10 to 150°C</td>
231     </tr>
232     <tr>
233     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
234     <td width="282">centrifuges</td>
235     </tr>
236     <tr>
237     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
238     <td width="282">filters (vacuum, pressure)</td>
239     </tr>
240     <tr>
241     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
242     <td width="282">dryers (vacuum, fluid-bed)</td>
243     </tr>
244     <tr>
245     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
246     <td width="282">evaporators</td>
247     </tr>
248     <tr>
249     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
250     <td width="282">solvent recovery system</td>
251     </tr>
252     <tr>
253     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
254     <td width="282">waste water pretreatment </td>
255     </tr>
256     </table>
257     </td>
258     </tr>
259     </table>
260     <p><font color="#CC6633">SYNTHESIS SM2 PLANT</font> </p>
261     <table width="500" border="0" cellspacing="0" cellpadding="0">
262     <tr>
263     <td width="186"><img src="fc/Pliva_07.jpg" width="204" height="204"></td>
264     <td width="314" valign="middle">
265     <table width="300" border="0" cellspacing="0" cellpadding="0">
266     <tr>
267     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
268     <td width="282">total volume: 66 m3 reactors/crystallizer</td>
269     </tr>
270     <tr>
271     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="11"></td>
272     <td width="282">unit volume: 0.5 - 6,3 m3</td>
273     </tr>
274     <tr>
275     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
276     <td width="282">material: glass lined, stainless steel</td>
277     </tr>
278     <tr>
279     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
280     <td width="282">temp. range: -10 to 150°C</td>
281     </tr>
282     <tr>
283     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
284     <td width="282">centrifuges</td>
285     </tr>
286     <tr>
287     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
288     <td width="282">filters (vacuum, pressure) </td>
289     </tr>
290     <tr>
291     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
292     <td width="282">dryers (vacuum, fluid-bed)</td>
293     </tr>
294     <tr>
295     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
296     <td width="282">evaporators </td>
297     </tr>
298     <tr>
299     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
300     <td width="282">solvent recovery system</td>
301     </tr>
302     <tr>
303     <td valign="top" width="18"><img src="fc/point_2.gif" width="35" height="12"></td>
304     <td width="282">waste water pretreatment </td>
305     </tr>
306     </table>
307     </td>
308     </tr>
309     </table>
310     </td>
311     </tr>
312     </table>

  ViewVC Help
Powered by ViewVC 1.1.26